-Use 1.2Hex Drivers
-Tightening torque : 5-8 Ncm

-Use 1.2 Hex Drivers
-Tightening torque : 5-8 Ncm

-Use 1.2Hex Drivers
-Tightening torque : 5-8 Ncm

-Oral fixtures are built on the working model

-Use for making general cement-type prosthesis
-Tapered body design facilitating prosthetic fit
-Cross-Section design for the prevention of prosthesis rotation
-Use a 1.2 Hex Driver
-Tightening torque : 30Ncm

-Use 1.2Hex Drivers
-Tightening Torque : NP 20Ncm, RP 30Ncm

-Use for the path adjustment of prosthesis
-Even/Odd two type hex connection overcoming the limitation of the abutment
-Use a 1.2Hex Driver
-Tightening torque : NP 20Ncm, RP 30Ncm

-Use for cases with path and aesthetic and spatial constraints
-After customization, be sure to use dental alloy for casting to make the prosthesis
Abutment ( CO-CR-MO Alloy) melting point 1,380℃ to 1,420℃
-Use a 1.2 Hex Driver
-Tightening torque : NP 20 Ncm, RP 30 Ncm

-Used for first drilling and cutting the bone slightly by 2~3mm
-Deciding the bone density by drilling
-Hand piece speed : 1,000~1,500RPM
-Used for previous drilling more deeply and cortical flaring
-Laser marking, regulating the length(except for 2.0/3.0)
-Drilling may be optional, depending on the bone density
-Hand Piece speed : 1,000~1,500RPM
-Used for side cutting when previous direction will be corrected
-The larger the diameter of drill, the smaller RPM
-Hand Piece speed : 1,000~1,500RPM
-As the last orifice expansion drill before implantation, it is smaller than the final selected implant diameter.
The thread height is about 0.5mm thin.
-Connecting ratchet adaptor
-Laser marking(15,25,35Ncm)
-Controlling the insertion force
-Choose the right size
-Used to remove gum tissue for alveolar bone inspection
-Checking for the first drilling direction and position
-Inserting into the 2.0 hole
-Extending the length of surgical drills
-Using in connecting abutment screw and Torque ratchet
-Torque control : 20Ncm(mini type), 30Ncm(standard type)
-If the bone quality is hard, it is a drill used after the formation of the final drill, and the final placement hole is more
It becomes wider, and implant placement becomes easier.
-Handpiece(Machine) & Ratchet type(torque screw driver)
-Long & Short type
-Fixture driver for handpiece used for taking out the fixture from fixture storage ample, in the beginning of implanting
-Torque control : 40Ncm

New idea for Mini Implant in Orthodontic Treatment
| H.P Driver(Short) | ![]() |
|---|---|
| H.P Driver(Long) | ![]() |
| Mini Handle | ![]() |
| Drill(1.2mm) | ![]() |
| Driver Shaft | ![]() |
| Universal Driver | ![]() |
| Ratchet Driver | ![]() |
|---|---|
| Ratchet Driver Tip | ![]() |
| Contra Angle Driver | ![]() |
| H.P Driver(Short, Long) | ![]() |